Elitech Inframate C CO2 Carbon Dioxide Leak Detector, R744 Refrigeration Heat Pump Leakage Tester, R-744 Gas Detector for HVACR

Inframate C Points
- Carbon Dioxide Detection* CO2-Specific infrared sensor is designed specifically for the detection of R744 (CO2) refrigerant leaks.
- Long Sensor Life* An infrared sensor can work up to 40,000 hours and its sensitivity won't degrade over time.
- Large TFT LCD Screen* Vividly displays leakage value, peak value, sensitivity level, battery power for very easy operation.
- Sensitivity Adjustable* With the highest sensitivity of 6g/year, and easy adjustment to medium (14/yr) and low (28g/yr) levels of sensitivity, the detector can help you quickly pinpoint leakage in various complex working conditions.
- Rechargeable Lithium Battery* Works up to 11 hours continuously on one full charge.
Parameter
| Sensor Type | Infrared |
| Sensor Sensibility | High: 6g/year; Medium: 14g/year; Low:28g/year |
| Sensor Life | 40,000 hours |
| Detectable Gases | R744 (CO2) |
| Auto OFF | After 10min of inactivity |
| Power | Two 18650 Lithium-ion Batteries |
| Battery Runtime | Up to 11 hours upon one full charge |
| Charging Time | Within 4hrs |
| Charging Voltage | DC 5V, 1A |
| Storage Temperature | -20°C~ 60°C (-4°F~ 140°F) |
| Operating Environment | Temperature: -10°C~ 52°C (-4°F~ 140°F) Humidity: Max.90% RH (non-condensing) |
| Alarm Mode | Audible and Visual |
| Tool Size | 201*72*35mm (7.9*2.8*1.4in.) |
| Tool Weight | 450g (15.9oz) |
| Certification | CE, SAE_J1627 |
Features
![]() |
![]() |
![]() |
|
Carbon Dioxide Detection* The high sensitivity of 6g/y for detection of R744 (CO2) refrigerant leaks |
Infrared Sensor* |
Sensitivity Adjustable* High/Medium/Low sensitivity selections to quickly pinpoint leakage in various environments |
![]() |
![]() |
![]() |
|
Large TFT Screen* Displays leakage value, peak value, sensitivity level, battery power vividly, for very easy operation |
Rechargeable Lithium Batteries* Works up to 11hrs on one full charge |
Backup Parts* An extension probe is included to extend probe distance. Five replacement filters are included for easy maintenance to better protect the sensor |
Elitech Inframate C Related Documents
- Elitech Inframate C CO2 Carbon Dioxide Leak Detector User Manual
- Elitech Inframate C Refrigerant Leak Detector ECM Certification


Product Information
Product Information
Shipping & Returns
Shipping & Returns







Elitech Inframate C CO2 Carbon Dioxide Leak Detector, R744 Refrigeration Heat Pump Leakage Tester, R-744 Gas Detector for HVACR
Elitech Inframate C CO2 Carbon Dioxide Leak Detector, R744 Refrigeration Heat Pump Leakage Tester, R-744 Gas Detector for HVACR

Inframate C Points
- Carbon Dioxide Detection* CO2-Specific infrared sensor is designed specifically for the detection of R744 (CO2) refrigerant leaks.
- Long Sensor Life* An infrared sensor can work up to 40,000 hours and its sensitivity won't degrade over time.
- Large TFT LCD Screen* Vividly displays leakage value, peak value, sensitivity level, battery power for very easy operation.
- Sensitivity Adjustable* With the highest sensitivity of 6g/year, and easy adjustment to medium (14/yr) and low (28g/yr) levels of sensitivity, the detector can help you quickly pinpoint leakage in various complex working conditions.
- Rechargeable Lithium Battery* Works up to 11 hours continuously on one full charge.
Parameter
| Sensor Type | Infrared |
| Sensor Sensibility | High: 6g/year; Medium: 14g/year; Low:28g/year |
| Sensor Life | 40,000 hours |
| Detectable Gases | R744 (CO2) |
| Auto OFF | After 10min of inactivity |
| Power | Two 18650 Lithium-ion Batteries |
| Battery Runtime | Up to 11 hours upon one full charge |
| Charging Time | Within 4hrs |
| Charging Voltage | DC 5V, 1A |
| Storage Temperature | -20°C~ 60°C (-4°F~ 140°F) |
| Operating Environment | Temperature: -10°C~ 52°C (-4°F~ 140°F) Humidity: Max.90% RH (non-condensing) |
| Alarm Mode | Audible and Visual |
| Tool Size | 201*72*35mm (7.9*2.8*1.4in.) |
| Tool Weight | 450g (15.9oz) |
| Certification | CE, SAE_J1627 |
Features
![]() |
![]() |
![]() |
|
Carbon Dioxide Detection* The high sensitivity of 6g/y for detection of R744 (CO2) refrigerant leaks |
Infrared Sensor* |
Sensitivity Adjustable* High/Medium/Low sensitivity selections to quickly pinpoint leakage in various environments |
![]() |
![]() |
![]() |
|
Large TFT Screen* Displays leakage value, peak value, sensitivity level, battery power vividly, for very easy operation |
Rechargeable Lithium Batteries* Works up to 11hrs on one full charge |
Backup Parts* An extension probe is included to extend probe distance. Five replacement filters are included for easy maintenance to better protect the sensor |
Elitech Inframate C Related Documents
- Elitech Inframate C CO2 Carbon Dioxide Leak Detector User Manual
- Elitech Inframate C Refrigerant Leak Detector ECM Certification


Original: $492.40
-65%$492.40
$172.34Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description

Inframate C Points
- Carbon Dioxide Detection* CO2-Specific infrared sensor is designed specifically for the detection of R744 (CO2) refrigerant leaks.
- Long Sensor Life* An infrared sensor can work up to 40,000 hours and its sensitivity won't degrade over time.
- Large TFT LCD Screen* Vividly displays leakage value, peak value, sensitivity level, battery power for very easy operation.
- Sensitivity Adjustable* With the highest sensitivity of 6g/year, and easy adjustment to medium (14/yr) and low (28g/yr) levels of sensitivity, the detector can help you quickly pinpoint leakage in various complex working conditions.
- Rechargeable Lithium Battery* Works up to 11 hours continuously on one full charge.
Parameter
| Sensor Type | Infrared |
| Sensor Sensibility | High: 6g/year; Medium: 14g/year; Low:28g/year |
| Sensor Life | 40,000 hours |
| Detectable Gases | R744 (CO2) |
| Auto OFF | After 10min of inactivity |
| Power | Two 18650 Lithium-ion Batteries |
| Battery Runtime | Up to 11 hours upon one full charge |
| Charging Time | Within 4hrs |
| Charging Voltage | DC 5V, 1A |
| Storage Temperature | -20°C~ 60°C (-4°F~ 140°F) |
| Operating Environment | Temperature: -10°C~ 52°C (-4°F~ 140°F) Humidity: Max.90% RH (non-condensing) |
| Alarm Mode | Audible and Visual |
| Tool Size | 201*72*35mm (7.9*2.8*1.4in.) |
| Tool Weight | 450g (15.9oz) |
| Certification | CE, SAE_J1627 |
Features
![]() |
![]() |
![]() |
|
Carbon Dioxide Detection* The high sensitivity of 6g/y for detection of R744 (CO2) refrigerant leaks |
Infrared Sensor* |
Sensitivity Adjustable* High/Medium/Low sensitivity selections to quickly pinpoint leakage in various environments |
![]() |
![]() |
![]() |
|
Large TFT Screen* Displays leakage value, peak value, sensitivity level, battery power vividly, for very easy operation |
Rechargeable Lithium Batteries* Works up to 11hrs on one full charge |
Backup Parts* An extension probe is included to extend probe distance. Five replacement filters are included for easy maintenance to better protect the sensor |
Elitech Inframate C Related Documents
- Elitech Inframate C CO2 Carbon Dioxide Leak Detector User Manual
- Elitech Inframate C Refrigerant Leak Detector ECM Certification